- Extra High Voltage (above 60kV) XLPE Power Cable
- Low Voltage (600V), Medium & High Voltage (25kV) XLPE Power Cable
- Building Wire & Cable
- Fire Resistant and Heat Resistant Cable
- Low Smoke Free Halogen Cable
- Solar PV Cable
- Water Resistant Cable
- Termite And Rodent Resistant Cable
- Rolling Stock Wire & Cable
- Aluminum Conductor & ACSR Power Cable
Low Smoke Free Halogen Cable
Low Smoke Free Halogen Cable
Product Description
Low Smoke Free Halogen Cable
General halogen (Chlorine, Fluorine etc.) materials have been widely applied on wires & cables because of its excellent properties on chemical resistance, oil resistance, flame retardant, and low price etc. However, the dense choking smoke and toxic gas (HCl, HF etc.) which cause obstruction to the personnel evacuation and rescue work during fire accident and also cause fatal accident and corrosion to mechanical equipment will be created during burning. More and more facts like “King's Cross fire on the underground rail system in London” can prove this. Besides composite material is not self-decomposable, it causes air pollution during burning. Due to the rise of environmental consciousness, people have gradually focused on the R&D of non-polluted materials and so Low Smoke Free Halogen materials were developed to solve this problem.
PEWC continues keeping its style and faith to research and successfully develops Low Smoke Free Halogen cable. For keeping safe of society and clean living space, we ask respectfully to our both old and new acquaintances to choose it.
Characteristics of Low-Smoke-Free-Halogen (LSFH)
LOW SMOKE EMISSION
Material | Smoke Density (#) |
---|---|
PVC | 350 |
Polychloroprene | 345 |
Chlorosulfonated Polyethylene | 360 |
Natural Rubber | 365 |
LSFH | 100 |
#: The test result is measured according to ASTM E662 with flaming mode for 4 minutes on the Smoke Density Chamber.
As the result shows, LSFH produced very low smoke density as compared with PVC (reduced to 30% under of that of PVC). Besides, the color of smoke is very light and will not cause pollution and obstruct the view.
HALOGEN-FREE
Toxic Gas (HCl or HF) will be emitted from halogen material during burning. If the HCl content in atmosphere exceeds over 1300ppm within a very short time, it will cause
lethal effect to animal.
Material | Acid Gas Emission (HCl mg/g) |
---|---|
PVC | 200~300 |
Flame Retardant PE | 150~200 |
Polychloroprene | 200~300 |
LSFH | 0 |
Remark: Acid Gas Emission Test is accordance with IEC 754-1.
As the results show, no HCl was emitted from LSFH material, so it will not cause any damage to human bodies or equipments.
EXCELLENT FLAME RETARDANT
Flame retardant is considered to avoid and postpone the spread of fire during fire accident so as to prevent expanding disaster area and reduce the disaster.
The comparison of LSFH and other materials is shown as follows:
Material | Oxygen Index |
---|---|
PVC | 33 |
Polychloroprene | 32 |
XLPE | 18 |
LSFH | 34 |
Remark:
Oxygen-Index O.I. is measured according to ASTM D 2863.
Non-combustible materials: O.I. ≥21
Self-extinguishable materials: O.I. ≥27
GENERAL DATA (Comparison with PVC)
Material Test Item | LSFH | PVC |
---|---|---|
Tensile Strength(kgf/mm²) | Min. 0.8 | Min. 1.0 |
Elongation(%) | Min. 100 | Min. 100 |
Aging Condition(℃/hours) | 100/48 | 100/48 |
Retention of Tensile Strength(%) | Min. 75 | Min. 85 |
Retention of Elongation(%) | Min. 65 | Min. 80 |
Oil Immersion Condition(℃/hours) | 70/4 | 70/4 |
Retention of Tensile Strength(%) | Min. 80 | Min. 80 |
Retention of Elongation(%) | Min. 65 | Min. 60 |
Volume Resistivity(Ω-cm) | Min.1015 | Min.1014 |
Flame Retardant | IEEE 383 & IEC 60332-3 | UL VW-1 |
Applications of Low-Smoke-Free-Halogen (LSFH)
Feature of LSFH Insulation
• Excellent Heat Resistance, able to withstand 90℃ on continuous operating condition
• Excellent Electrical Properties, Volume Resistivity is higher than 1015Ω-cm
• Excellent Oil Resistance
• Excellent Flame Retardant, successfully passed the flame test of IEEE 383 (Vertical Tray Flame Test)
• Low Smoke Density, Halogen-Free
Feature of LSFH Outer-sheath
• Physical Properties are superior to PVC
• Excellent Heat Resistance, able to withstand 90℃ on continuous operating condition
• Excellent Oil Resistance
• Excellent Flame Retardant, successfully passed the flame test of IEEE 383 (Vertical Tray Flame Test)
• Low Smoke Density, Halogen-Free
Application Fields of LSFH Cable
• General Indoor Wiring
• Automobile Wiring
• Lead Wire
• High & Low Voltage Transmission & Distribution Wiring
• Control Panel Wiring
• Heat Resistant/Fire Resistant Cable
• Shipboard Cable